Details
Cataloging Information
Mechanical treatments
Overview
Background
Smoldering underground fires in peatlands are among the most persistent and destructive wildfire types, but resisting conventional suppression methods.
Aims
This study experimentally evaluates a heat-pipe-based underground firebreak concept as a passive cooling strategy to mitigate smoldering propagation in stratified peat profiles.
Methods
Laboratory-scale experiments were conducted with an upper dry peat layer overlying a saturated layer. Heat pipes of varying lengths, geometries and quantities were installed with the condenser section positioned at the dry–saturated interface.
Key results
Under these conditions, heat pipes reduced peak smoldering temperatures and, in some configurations, quenched combustion. The intervention expanded the high-moisture, non-combustible region (‘safe zone’) more than fivefold compared with control tests. Longer pipes and configurations with larger condenser surface areas demonstrated greater thermal suppression effects.
Conclusion
The results provides a laboratory-scale proof of concept that heat pipes can function as passive thermal sinks and promote moisture redistribution at the dry–saturated interface in peat columns.
Implications
These findings are limited to controlled laboratory experiments. Substantial additional experimental, modeling and field research are required before assessing real-world deployment potential.
Citation
Access this Document
Treesearch
publication access with no paywall
Check to see if this document is available for free in the USDA Forest Service Treesearch collection of publications. The collection includes peer reviewed publications in scientific journals, books, conference proceedings, and reports produced by Forest Service employees, as well as science synthesis publications and other products from Forest Service Research Stations.